Mains-powered carbon monoxide alarm with non-replaceable, sealed-in Lithium battery for 7 years of continuous protection, that can be interconnected with up to 23 other Kidde mains alarms (of which 18 can be initiating alarms).
Shipping Information
Only cards registered to Irish banks can be accepted. We apologise if there is any inconvenience.
Interconnectable – with other Kidde and Firex mains smoke, heat and CO alarms on a single wiring network using ‘Smart Interconnect’ technology
Monitors the air – every 15 seconds for the presence of carbon monoxide
Tamper-resistant locking device – prevents unauthorised removal without the use of a tool
End-of-life warning – after 7 years from initial power-up
Test/Reset button – to allow regular testing of alarm function
Rechargeable Lithium battery – provides 7 years of continuous operation in the event of mains failure
WHERE TO USE
This Kidde hard-wired carbon monoxide alarm is ideal for new builds, major refurbishments of existing properties or complete re-wiring projects and can be wall or ceiling mounted, and requires installation by a professionally qualified electrician. Complies with UK Building Regulations for new housing and associated standards (BS EN 50292 code of practice).
GENERAL FEATURES
Model
4MCO
Power Supply
230V mains-powered with rechargeable Lithium back-up battery
Temperature Range
0ºC to +40ºC
Humidity Range
5%-95% relative humidity (RH) non-condensing
Storage and Transport
-20ºC to +60ºC and 5–95% relative humidity (RH) non-condensing
Alarm Dimensions
147 x 147 x 42mm
Alarm Weight
350g
Warranty
7 years
Approvals
BSI certified to BS EN50291: 2010 CE tested and certified
TECHNICAL SPECIFICATION
Sensor
Electrochemical with de-ionised water electrolyte, sampling one every 15 seconds
Button Test
Simulates the effect of CO at the sensor, checks electronics and sounder
Supply Voltage
230V AC, 50Hz (nominal UK voltage)
Audible Alarm
85 dB at 3 metres
Power Consumption
230V AC; 50Hz; 30mA max per alarm
Connection
To be in accordance with the latest IEE Regulations, BS7671, via a supplied cable harness
To be in accordance with the latest IEE Regulations, BS7671, via supplied cable harness
Alarm Response
30ppm* = no alarm within 120 minutes 50ppm* = must alarm within 60-90 minutes 100ppm* = must alarm within 10-40 minutes 300ppm* = must alarm within 3 minutes * Parts per million